Cloud by points/element Tool Default settings

In Microstation we have the ability to set the default settings of the Cloud by point/element tool to an arc radius of 5. I've been advise through a service ticket that the cloud by element/points tool resets every time OUS is started. Therefore h...
14 days ago in Substation / Other 0 Needs review

Add Cable Label

Hi, We are hoping to label a cable and its cores at both ends of the cable (mostly across different drawing pages/sets). Currently the software is built for cables to be shown just once - at one end only. We can see that the cable can be duplicate...
about 1 month ago in Substation / Schematic Diagrams 0 Needs review

OpenGis-Speichrung von Texten/Beschriftungen - Erweiterung um Text-Ausrichtung

Die Kennziffer der Text-Ausrichtung soll als eine separate Spalte (z.B. MS_TEXT_JUST) in den _GEOM_BEST-Tabellen mitgespeichert werden. Dabei soll nicht einfach der Standardwert des Parameters bJust/tJust aus der 30-er FS-Zeile, sondern die tatsä...
9 days ago in sisNET 1 Needs review

OpenGis-Speicherung von Multilinien - zusammen mit Mittellinie

Zur Zeit können Multilinien in den _GEOM_BEST-Tabellen wie folgt gespeichert werden (steuerbar über die Spalte N_OG_SETTINGS.STORINGTYPE): STORINGTYPE = 0: SdoType 2003 (Polygon) - Außenlinien + Endkappen (als Fläche) STORINGTYPE = 2: SdoType 20...
9 days ago in sisNET 1 Needs review

Automatische Änderung der Beschriftungs-Priorität

Es sollte die gleichzeitige / automatische Änderung der Beschriftungs-Priorität bei Änderung der Priorität von Haupt-Grafik ermöglicht werden, so dass bei der Ausführung des FS-Befehls "GRAFIK_PRIORITAET=<Haupt-Prio>" die Beschriftungs-Prior...
10 days ago in sisNET / Other 1 Needs review

IMB Connector: zusätzlicher Objekttyp - SAP-Aufträge

Über den IMB Connector können Equipments (EQUI), Technische Plätze (FLOC) und Meldungen (NOTIF) gekoppelt werden. Es sollte zusätzlich möglich sein, Aufträge (SAP T-Code IW33) in GIS und SAP zu koppeln. In unseren sisNET-Projekten erfassen wir im ...
about 1 month ago in sisNET / Other 1 Needs review

Supress Device ID - ON/OFF toggle

A quick toggle ON/OFF button for 'Supress Device ID' would be handy and more efficient than having to enter the Device Properties dialog box each time. Thanks Jess - Essential Energy
about 1 month ago in Substation / Other 0 Needs review

UNDO does NOT Work in Substation. Need UNDO in Substation

Undoing actions in Substation does NOT behave as expected. We are told by Bentley Substation Support that the Undo is a MicroStation command and the Undo is not supported in Substation since more operations can be hidden (like e.g. a database acti...
3 months ago in Substation / Engineering Design 0 Needs review

Undo/redo button for placing smartobjects

Need undo / redo button for smartobjects placed by openutilities smartools such as equipment, cables, grids ect.
3 months ago in Substation / Other 1 Needs review

More than one file open at a time

Hi, I believe we cannot open more than one file in Substation due to our integration with ProjectWise. This results in great loss of productivity and ease. Instead, we have to open a file/s in read-only from ProjectWise in a different application ...
3 months ago in Substation 3 Needs review