Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

OpenUtilities Electrical (Promis.e)

Showing 17

Use Page Descriptions attributes directly in text

The idea is to allow use Page Description attributes directly in text, like Attributes in Microstation. The background for that idea is our complication with Title Blocks. Our each project comprises of a lot of page formats (we are not using ISO/D...
5 months ago in OpenUtilities Electrical (Promis.e) 0 Needs review

Exchange symbol to another in device with family assigned

Let's say we have device with assigned family. Each family child have 3 alternates (different symbols): Child.1.alt.1 with symbol X1, Child.1.alt.2 with symbol X2, Child.1.alt.3 with symbol X3, The idea is to easily exchange symbol to another defi...
7 months ago in OpenUtilities Electrical (Promis.e) 0 Needs review

Place device again

To speed up placing another child devices of already placed devices, a function "Place device again" will be great. Idea: 1) Right-click on device 2) Just below "Place symbol again", create command "Place device again" 3) A pop-up window appear, a...
7 months ago in OpenUtilities Electrical (Promis.e) 0 Needs review

Add wiring numbering rule for short wire segments

I've had problems where promise would assign a wire number on a short wire segment that cannot display the information properly (see attachment), I can select HIDE but it can be time consuming if there many of them or if they reappear. It would be...
8 months ago in OpenUtilities Electrical (Promis.e) 0 Needs review

Ability to export AutomationML (AML) files

Can we please have the ability to export an AutomationML (AML) file for use with PLC programming software. This would save a huge amount of duplication work.... Basically, the same as EPlan - Importing EPLAN Electric P8 into OMRON Sysmac Studio (r...
about 1 year ago in OpenUtilities Electrical (Promis.e) 0 Needs review

Apply Dark Theme to Project Manager

When Dark Theme is applied, it should affect Project Manager also
over 1 year ago in OpenUtilities Electrical (Promis.e) 0 Needs review

Spacing - Individual cross-reference for PLC table

I am setting up a PLC table and I have found that the PLC cross-reference text is a single attribute. This differs to the relating components; PLC Address and Function Text which are individual attributes. Due to the cross-reference text being a s...
over 1 year ago in OpenUtilities Electrical (Promis.e) 0 Already exists