Add Cable Label

Hi, We are hoping to label a cable and its cores at both ends of the cable (mostly across different drawing pages/sets). Currently the software is built for cables to be shown just once - at one end only. We can see that the cable can be duplicate...
30 days ago in Substation / Schematic Diagrams 0 Needs review

IMB Connector: zusätzlicher Objekttyp - SAP-Aufträge

Über den IMB Connector können Equipments (EQUI), Technische Plätze (FLOC) und Meldungen (NOTIF) gekoppelt werden. Es sollte zusätzlich möglich sein, Aufträge (SAP T-Code IW33) in GIS und SAP zu koppeln. In unseren sisNET-Projekten erfassen wir im ...
21 days ago in sisNET / Other 1 Needs review

Supress Device ID - ON/OFF toggle

A quick toggle ON/OFF button for 'Supress Device ID' would be handy and more efficient than having to enter the Device Properties dialog box each time. Thanks Jess - Essential Energy
29 days ago in Substation / Other 0 Needs review

Export info on the Xsection O/S Review dialog

When several O/S are assigned to a single fiber, the Fiber Review of the cable doesn´t show all of them. Even if you export it, it still doesn´t be shown. All the OS of a fiber cable are shown in the Xsection O/S Review. Would it be possible to ex...
8 days ago in OpenComms / Reporting 0 Future consideration

categorize polygons by customizable attributes

generate a polygon in a fully customizable geographic area according to the designer´s needs, for example, by clients, optical fiber, coaxial, strand, and that can be classified by type
11 months ago in OpenComms / Engineering Design 0 Future consideration

UNDO does NOT Work in Substation. Need UNDO in Substation

Undoing actions in Substation does NOT behave as expected. We are told by Bentley Substation Support that the Undo is a MicroStation command and the Undo is not supported in Substation since more operations can be hidden (like e.g. a database acti...
2 months ago in Substation / Engineering Design 0 Needs review

reply the "SET COAX BUILD STATE" Tool, in the Fiber Module

No description provided
11 months ago in OpenComms / Engineering Design 0 Planned

BOM REPORT FROM FIBER MODULE & STRAND MODULE

IN THE COAXIAL MODULE WHEN WE MAKE A BOM REPORT, THE INFORMATION COMES OUT INCLUDING THE DATA FROM THE STRAND MODULE. WE NEED THE FIBER MODULE, WHEN MAKING A BOM REPORT, TO ALSO GET INFORMATION FROM THE STRAND MODULE TO WHICH IT IS LINKED.
10 months ago in OpenComms / Reporting 0 Future consideration

Undo/redo button for placing smartobjects

Need undo / redo button for smartobjects placed by openutilities smartools such as equipment, cables, grids ect.
3 months ago in Substation / Other 1 Needs review

More than one file open at a time

Hi, I believe we cannot open more than one file in Substation due to our integration with ProjectWise. This results in great loss of productivity and ease. Instead, we have to open a file/s in read-only from ProjectWise in a different application ...