OpenUtilities Electrical (Promis.e)

Showing 9

User without any role in command protection

Currenlty a user without any roles assigned in Command Protection are able to access all the commands without any restrictions. Hence by implementation of this enhancement one of the below two needs to be implemented incase when a Command Protecti...
3 months ago in OpenUtilities Electrical (Promis.e) 0 Future consideration

Promis-e app to have a configuration for Promis-e timeout after maximum single session.

This is a requirement for all the apps used by SOLAR moving forward. This came up after the security assessment. As promis-e data is very sensitive data, we like to get notify some sort when user are working on it. for Example, If a use uses the a...
4 months ago in OpenUtilities Electrical (Promis.e) 0 Needs review

Exchange symbol to another in device with family assigned

Let's say we have device with assigned family. Each family child have 3 alternates (different symbols): Child.1.alt.1 with symbol X1, Child.1.alt.2 with symbol X2, Child.1.alt.3 with symbol X3, The idea is to easily exchange symbol to another defi...
about 2 months ago in OpenUtilities Electrical (Promis.e) 0 Needs review

Place device again

To speed up placing another child devices of already placed devices, a function "Place device again" will be great. Idea: 1) Right-click on device 2) Just below "Place symbol again", create command "Place device again" 3) A pop-up window appear, a...
about 2 months ago in OpenUtilities Electrical (Promis.e) 0 Needs review

Add wiring numbering rule for short wire segments

I've had problems where promise would assign a wire number on a short wire segment that cannot display the information properly (see attachment), I can select HIDE but it can be time consuming if there many of them or if they reappear. It would be...
2 months ago in OpenUtilities Electrical (Promis.e) 0 Needs review

device id hiding

on selecting of multiple symbol and By one click we can hide all its same device if.Eg. for terminals we have a same device id so by selecting of all we can hide its device id
6 months ago in OpenUtilities Electrical (Promis.e) 0 Needs review

Ability to export AutomationML (AML) files

Can we please have the ability to export an AutomationML (AML) file for use with PLC programming software. This would save a huge amount of duplication work.... Basically, the same as EPlan - Importing EPLAN Electric P8 into OMRON Sysmac Studio (r...
9 months ago in OpenUtilities Electrical (Promis.e) 0 Needs review

Apply Dark Theme to Project Manager

When Dark Theme is applied, it should affect Project Manager also
10 months ago in OpenUtilities Electrical (Promis.e) 0 Needs review

Spacing - Individual cross-reference for PLC table

I am setting up a PLC table and I have found that the PLC cross-reference text is a single attribute. This differs to the relating components; PLC Address and Function Text which are individual attributes. Due to the cross-reference text being a s...
12 months ago in OpenUtilities Electrical (Promis.e) 0 Already exists