Exchange symbol to another in device with family assigned

Let's say we have device with assigned family. Each family child have 3 alternates (different symbols): Child.1.alt.1 with symbol X1, Child.1.alt.2 with symbol X2, Child.1.alt.3 with symbol X3, The idea is to easily exchange symbol to another defi...
9 months ago in OpenUtilities Electrical (Promis.e) 0 Needs review

Place device again

To speed up placing another child devices of already placed devices, a function "Place device again" will be great. Idea: 1) Right-click on device 2) Just below "Place symbol again", create command "Place device again" 3) A pop-up window appear, a...
9 months ago in OpenUtilities Electrical (Promis.e) 0 Needs review

Include the field "Discipline" as a possible filter option on the reports

Sometime for us is import to create reports filtering also the field "Discipline", for example, we only want to know the clamps quantity into the design.
over 1 year ago in Substation / Reporting 6 Already exists

Automatic update of fiberspan length

When a span is generated, the length measurement is automatic. We also request that it be automatic when making edits (extended Fiberspan, Move box and Fiberspan, for example)
over 1 year ago in OpenComms / Engineering Design 1 Future consideration

Add wiring numbering rule for short wire segments

I've had problems where promise would assign a wire number on a short wire segment that cannot display the information properly (see attachment), I can select HIDE but it can be time consuming if there many of them or if they reappear. It would be...
9 months ago in OpenUtilities Electrical (Promis.e) 0 Needs review

Batch Check In for ProjectWise on Project wide commands

When we have multiple pending changes and we want to refresh the project drawings with the changes we are require to check in every drawing that the refresh drawings command opens - this is very time consuming. Basically, the check in dialog appea...
over 1 year ago in Substation / File Management 2 Future consideration

Alphabetical sorting / listing of the Levels When placing a cable

Hello, Request for the alphabetical sorting / listing of the Levels When placing a cable, please; It is very difficult for us to choose the right level if not alphabetically listed. Thanks, Nicolas Tobbackx
over 1 year ago in Substation / Engineering Design 0 Future consideration

Make a function to change a 3D cable phase.

Right now to change a phase of one conductor it is necessary to use the properties tool, which is difficult for starter users (it is required otherwise you mess with the level that the software uses to insert clamps into the conductors). My idea i...
over 1 year ago in Substation / Engineering Design 0 Planned

In BOUD, we need to be able to drag and organize features within a point.

Useful for reviews, last-minute edits, etc.
almost 2 years ago in Designer / Engineering Design 2 Planned

Option "dunkel gehaltene Benutzeroberfläche" - alle Schaltflächen etc. dunkel darstellen

Bei eingestelltem dunklen Modus im sisNET (Connect Edition Version 10.17.7.17) werden einige Oberflächen nicht dunkel dargestellt. Siehe Beispiele angefügte PDF