Ability to work directly on rpt files present in PW
As of the time of writing when we edit a rpt file on a managed configuration on ProjectWise. For saving those modifications we must export it via a save as and then re-import it on the PW document. It would be much easier if the save button saved ...
Hi, We are hoping to label a cable and its cores at both ends of the cable (mostly across different drawing pages/sets). Currently the software is built for cables to be shown just once - at one end only. We can see that the cable can be duplicate...
A quick toggle ON/OFF button for 'Supress Device ID' would be handy and more efficient than having to enter the Device Properties dialog box each time. Thanks Jess - Essential Energy
Hi, During our design/drafting planning stage we may draft up (without any intelligence) a 'dummy' symbol that is required to be formally created as a symbol and part. This allows for spacing in the drawing to be set out and for the designer to de...
Grounding Grid need choice more Levels Linestyles=Cable Type
Hello, Ref. Video Recording MS Teams call 29 Mar 2023 with Bentley Substation Support Mr Satish Saptasagar and Mr Sebastian Wantuch. For Grounding Grid : Need visual distinction (= different Linestyles) between each type of cable. Need to be able ...
You have two options to insert the balloons, horizontal and vertical. My idea is to add a third option, which is going to insert the balloons into the horizontal but grouped in the vertical (today it groups the balloons only in the horizontal).
One click change between Insert cable/objects functions
When with the "Insert Substation Objects" function opened, make it possible to choose other functions without getting out of the function window. It would be great if you make that change, because right now is not possible to change between the "I...
Batch Check In for ProjectWise on Project wide commands
When we have multiple pending changes and we want to refresh the project drawings with the changes we are require to check in every drawing that the refresh drawings command opens - this is very time consuming. Basically, the check in dialog appea...
Alphabetical sorting / listing of the Levels When placing a cable
Hello, Request for the alphabetical sorting / listing of the Levels When placing a cable, please; It is very difficult for us to choose the right level if not alphabetically listed. Thanks, Nicolas Tobbackx
Insert Symbol By ID not saving the dialogue position
Hi there, It has been suggested that I create an enhancement regarding a view setting for the Insert Symbol By ID dialog box that does not seem to be saving. It seems that each time we go into this dialog box we have to drag up the bottom section ...