Objekt- / Dateikonsistenz reparieren

Wenn in einem Job der Fehler "Fehler beim Lesen der Grafik! [Objekttyp],ID: [MSLINK] (Doppelte ID!)" auftritt, kann die doppelte Grafik über die Funktion "Job reparieren" gelöscht werden. Tritt dieser Fehler in einer Poolkarte auf, lässt sich die ...
9 months ago in sisNET / Other 1 Needs review

Richtige Einfügepunkte für TFO und Beschriftungen in _GEOM_BEST

Bei der Geometriespeicherung von textförmigen Objekten und Beschriftungen werden in den _GEOM_BEST-Tabellen stets die Koordinaten der linken unteren Ecke des Textes gespeichert. Stattdessen sollten die Koordinaten des richtigen Einfügepunkts (Text...
9 months ago in sisNET / Other 1 Needs review

Grounding Grid need choice more Levels Linestyles=Cable Type

Hello, Ref. Video Recording MS Teams call 29 Mar 2023 with Bentley Substation Support Mr Satish Saptasagar and Mr Sebastian Wantuch. For Grounding Grid : Need visual distinction (= different Linestyles) between each type of cable. Need to be able ...
over 1 year ago in Substation / Construction Prints 4 Future consideration

Promis-e app to have a configuration for Promis-e timeout after maximum single session.

This is a requirement for all the apps used by SOLAR moving forward. This came up after the security assessment. As promis-e data is very sensitive data, we like to get notify some sort when user are working on it. for Example, If a use uses the a...
10 months ago in OpenUtilities Electrical (Promis.e) 0 Needs review

Balloons grouped in the vertical position

You have two options to insert the balloons, horizontal and vertical. My idea is to add a third option, which is going to insert the balloons into the horizontal but grouped in the vertical (today it groups the balloons only in the horizontal).
over 1 year ago in Substation / Construction Prints 1 Future consideration

device id hiding

on selecting of multiple symbol and By one click we can hide all its same device if.Eg. for terminals we have a same device id so by selecting of all we can hide its device id
11 months ago in OpenUtilities Electrical (Promis.e) 1 Needs review

Create a Rectangle shape for a conduit in DUCT

There are currently only 4 types of shapes that define a conduit type. With the addition of a rectangle shape we can closely resemble a TRAY configuration. The square type doesn't define the area correctly for this application.
about 1 year ago in OpenComms / Engineering Design 0 Future consideration

modify the work flow for strand placement

when drawing strand i would like to place the pole number and then the house count.
over 1 year ago in OpenComms / Engineering Design 1 Future consideration

Add Navigate to Terminal/Pin-Plug Manager

When right-click on particular terminal number, add "Navigate" to navigate to particular page.
5 months ago in OpenUtilities Electrical (Promis.e) 0 Needs review

Use Page Descriptions attributes directly in text

The idea is to allow use Page Description attributes directly in text, like Attributes in Microstation. The background for that idea is our complication with Title Blocks. Our each project comprises of a lot of page formats (we are not using ISO/D...
5 months ago in OpenUtilities Electrical (Promis.e) 0 Needs review